Product List
(Total 64 Products )
View:
List View
Gallery View
Min. Order: 8 Pieces
- Type and Specification: Bhd2-25(40, 100, 200, 400)/380, 660, 1140(2t, 3t)
- Rated Current(a): 25, 40, 100, 200, 400
- Rated Voltage(V): 380, 660, 1140
- Cable Entry Quantiy: Main 2, 3, 4 Branch 0, 2
- Max. Cable O. D. (Mm): 9~15, 8~20, 19~36, 22~49, 42~78
- Outline Dimension(L*W*H)(Mm): 260*125*75, 300*130*112, etc.
Min. Order: 1 Set
- Rated Voltage(Kv): 3.6-7.2-12
- Rated Short Circuit Breaking Current(Ka): 20, 25, 31, 5
- Rated Current(a): 630~1250
- Rated Current Withstand for Short Time: 20ka, 25ka, 31.5ka
- Rated Current Withstand Peak Value(Ka): 50, 63, 80
- Rated Short Circuit Connecting Current: 50ka, 63ka, 80ka
Min. Order: 1 Set
- Rated Voltage(Kv): 3.6-7.2-12
- Rated Short Circuit Breaking Current(Ka): 20, 25, 31.5
- Rated Current(a): 630~1250
- Rated Withstanding Current for Shor Time: 20ka, 25ka, 31.5ka
- Rated Peak Withstanding Current Value: 50ka, 63ka, 80ka
- Rated Duration for Short Circuit(S): 4
Min. Order: 1 Set
- Rated Voltage((Kv: 3, 6, 10
- Max. Voltage(Kv): 3.6, 7.2, 12
- Rated Frequency(Hz): 50
- Rated Current of Breaker(a): 630, 1250, 1600, 2000, 2500, 3150
- Rated Current of Switch Cabinet(a): 630, 1250, 1600, 2000, 2500, 3150
- Rated Current for Heat Stability(4s)(Ka): 20, 25, 31.5, 40, 50
Min. Order: 1 Set
- Rated Voltage(V): 127, 380, 660, 1140
- Rated Current(a): 1000
- Rated Working System: Permanent
- Transport Package: Fumigated Wooden Box
- Specification: 1pc/ctn
- Trademark: OEM, ODM
Min. Order: 1 Set
- Type and Specification: No. 5.0~7.1/2*5.5~7.1
- Fan No.: 5.0~7.1
- Air Volume Range(M3/Min): 130~240, 180~300, 180~350, etc.
- Static Pressure Range(PA): 340~2930, 340~3200, 400~4000, etc.
- Power(%): ≥ 75± 5
- Lsa dB(a) Nosie: ≤ 25
Min. Order: 1 Set
- Rated Capacity(kVA): 50~4000
- High Voltage(Kv): 6, 10
- Low Voltage(Kv): 0.693~3.45
- Connecting Way: Yd0(D11) Ydo(D11)Dyn11
- Loss(W): Empty 350~7000, Loading 550~15000
- Empty Load Current (%): 0.7~2.5
Min. Order: 1 Set
- Rated Voltage(V): 380(660, 1140)
- Motor Control Power(Kw): 40(60, 65, 100, 150, 170, 250)
- Entry Cable O. D. (Mm): Main Circuit 19~51(12~40, 28~63)Control Circuit
- Outline Dimension(L*W*H)(Mm): 1196*575*842(1196*625*901)
- Weight(Kg): 445(545)
- Transport Package: Carpet, Fumigated Wooden Box
Min. Order: 1 Set
- Type and Specification: Qjz3-30(60, 80, 120, 200) /660(380) or 1140(660)
- Rated Current(a): 30, 60, 80, 120, 200
- Rated Voltage(V): 660(380) 1140(660)
- Motor Control Power(Kw): 15~250
- Entry Cable O. D(Mm): Main Circuit 12~30/19~51, Control Circuit 8~19
- Outline Dimension(L*W*H)(Mm): 425*343*540/650*446*742/650*455*780
Min. Order: 1 Set
- Type and Specification: Qjz3-30(60, 80, 120, 200)/660(380)N or 1140(660)N
- Rated Current(a): 30, 60, 80, 120, 200
- Rated Voltage(V): 660(380) 1140(660)
- Motor Control Power(Kw): 15~170
- Entry Cable O. D. (Mm): Main Circuit 19~51 Control Circuit 8~19
- Outline Dimension(L*W*H)(Mm): 650*446*742(650*445*789)
Min. Order: 1 Set
- Type and Specification: Qbz2-30(60, 80, 120, 200)/660(380) or 1140(660)
- Rated Current(a): 30, 60, 80, 120, 200
- Rated Voltage(V): 380, 660, 1140
- Motor Control Power(Kw): 15~170
- Entry Cable O. D. (Mm): Main Circuit 12~30(40) 1~51 Control Circuit 8~19
- Outline Dimension(L*W*H)(Mm): 425*290*540/535*420*545/535*456*672/650*446*742
Min. Order: 1 Set
- Type and Specification: Qbz2-30(60, 80, 120, 200)/660(380)N or 1140(660)N
- Rated Current(a): 30, 60, 80, 120, 200
- Rated Voltage(V): 15~250
- Entry Cable O. D. (Mm): Main Circuit 12~30(19~51) Control Circuit 8~19
- Outline Dimension(L*W*H)(Mm): 425*343*540/564*446*723/650*446*742/650*455*780
- Weight(Kg): 57, 108, 120, 123, 132
Min. Order: 1 Set
- Type and Specification: Qbz-2*30(60, 80)/1140(660)
- Rated Current(a): 30, 60, 80
- Rated Voltage(V): 380, 660, 1140
- Motor Control Power(Kw): 15, 25, 30, 40, 50, 65, 100
- Entry Cable O. D. (Mm): Main Circuit 19~51 Control Circuit 8~19
- Outline Dimension(L*W*H)(Mm): 680*655*710/670*422*575
Min. Order: 1 Piece
- Feature: Mini Size
- Rated Voltage(V): AC127
- Power(W): ≤ 30
- Horizontal Definition: 350tvl
- Gray Identified Level: 7
- Outline Dimension(D*L)(Mm): 152*435
Min. Order: 1 Set
- Type and Specification: Qjgr(2)-75(150, 250, 300, 400)
- Rated Voltage(Kv): 3.3, 6, 10
- Rated Current(a): 75, 150, 250, 300, 400
- Controlled Motor Power(Kw): 300~4980
- Cable Entrance(Mm): 42~78, 8~19
- Weight(Kg): 2800
Min. Order: 1 Set
- Type and Specification: Pjg-800A(1000A, 1250A)/3.3y/6y/10y
- Rated Voltage(Kv): 3.3/6/10
- Rated Current(a): 800, 1000, 1250
- Rated Breaking Current(Ka): 31.5
- Rated Peak Current(Ka): 80
- Rated Short Crcuit Duration(S): 4
Min. Order: 1 Set
- Type and Specification: Pjg(1)-3.3A(6A/10A)/3.3(Y)-6(Y)-10(Y)
- Rated Voltage(Kv): 3.3/6/10
- Rated Current(a): 50~630
- Rated Connecting(Breaking) Current(Ka): 12.5
- Rated Peak Current(Ka): 31.5
- Rated Short Circuit Duration(S): 2
Min. Order: 1 Set
- Type and Specification: Qjgz(1)-(50A~630A)/3.3/6/10
- Rated Current(a): 50~630
- Rated Breaking Current (Ka): 8 I E
- Rated Connecting Current(Ka): 10 I E
- Rated Tolerated Peak Current Value(Ka): 31.5
- Rated Short Circuit Duration(S): 2
Min. Order: 1 Set
- Type and Specification: Kjg-50~630A/6y(10y)
- Rated Voltage(Kv): 6(10)
- Rated Current(a): 50~630
- Rated Short Circuit Breaking Current(Ka): 12.5
- Rated Tolerated Peak Current Value(Ka): 31.5
- Rated Short Circuit Duration(S): 2
Min. Order: 1 Set
- Type and Specification: Bxb-50A~1250A/3300V(1140V, 660V, 380V)
- Rated Voltage(Kv): 0.38/0.66/1.14/3.3
- Rated Current(a): 50~1250A
- Cable O. D. (Mm): Main Control 42~78 Control Circuit 8~19
- Outline Dimension(L*W*H)(Mm): 574*882*732
- Weight(Kg): 255
Min. Order: 1 Set
- Type and Specification: Qjz-800(1600)/3300-2, 4, 6, 8
- Rated Voltage(V): 3300
- General Current(a): 800, 1000
- Isolation Switch(Qty): 1(800A) 2(1000A)
- Single Cirucuit Current(a): 400
- Outline Dimension(W*D*H)(Mm): 2544*1320*1092(800A) 3475*1320*1292(1600A)
Min. Order: 1 Set
- Type and Specification: Zjz2-4.0(6, 8, 10)/1140(660)M, 660(380)M
- Rated Voltage(V): 380(660, 1140)/133
- Rated Current(a): 6.08/17.36, etc.
- Rated Capacity(kVA): 4, 6, 8, 10
- Insulation Grade: B
- Entry Cable O. D. (Mm): Main Circuit 12~30, 8~19 Control Circuit 8~12
Min. Order: 1 Piece
- Type and Specification: Lbg1-200(400)/6(10)a
- Rated Voltage(V): 6, 10
- Rated Current(a): 200, 400
- Limit Passing Current(a): Virtual Value 9, 12 Peak Value 15, 20
- Dynamic-Thermal Stablity Current(Ka): Thermal Stability (3.15, 6.3) Dynamic 7.84, 14
- Matched Cable′s Max. O. D. (Mm): 78
Min. Order: 24 Pieces
- Type: Mining lamp
- IP Rating: IP66
- Rated Capacity(Ah): 4.0
- Nomial Voltage(V): 3.2
- Lighting Time(H): ≥ 20
- Current of Main Lamp(a): ≤ 2